{"id":1882,"date":"2025-04-14T09:33:34","date_gmt":"2025-04-14T09:33:34","guid":{"rendered":"https:\/\/webprojects.cloud\/wordpress\/splatco\/?post_type=spl_knowledgebase&#038;p=1882"},"modified":"2025-06-10T08:44:49","modified_gmt":"2025-06-10T08:44:49","slug":"sx10501-power-supply-requirements","status":"publish","type":"spl_knowledgebase","link":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/","title":{"rendered":"SX10501: Power supply requirements"},"content":{"rendered":"\n<p>The board will run off 12VDC to 24VDC. Maximum current draw (TTL interface, RS485 termination link open) is 30mA. Using RS485 and 75 Ohms of termination, the maximum current draw is 90mA. The voltage is allowed to go to a maximum of 32V.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"265\" height=\"106\" src=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg\" alt=\"\" class=\"wp-image-1883\" srcset=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg 265w, https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power--64x26.jpg 64w\" sizes=\"auto, (max-width: 265px) 100vw, 265px\" \/><\/figure>\n\n\n\n<p>Connect power to the 3-pin connector depicted above. The positive terminal is in the middle. There are 2 ground pins simply because we used a 3-pin connector to make it unique.<\/p>\n\n\n\n<p>You can use the same power supply as for the controller and other boards in your system, or a separate one. However, the ground (0V) terminals (see\u00a0<a href=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-controllers\/cc18-product-documentation\/cc18-introduction\/some-common-terminology\/\">Some common terminology<\/a>) of all power supplies and boards must all be connected together or smoke will come out.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The board will run off 12VDC to 24VDC. Maximum current draw (TTL interface, RS485 termination link open) is 30mA. Using RS485 and 75 Ohms of&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1870,"menu_order":3,"template":"","class_list":["post-1882","spl_knowledgebase","type-spl_knowledgebase","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SX10501: Power supply requirements - SPLat Controls<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SX10501: Power supply requirements - SPLat Controls\" \/>\n<meta property=\"og:description\" content=\"The board will run off 12VDC to 24VDC. Maximum current draw (TTL interface, RS485 termination link open) is 30mA. Using RS485 and 75 Ohms of...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/\" \/>\n<meta property=\"og:site_name\" content=\"SPLat Controls\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-10T08:44:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"265\" \/>\n\t<meta property=\"og:image:height\" content=\"106\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/\",\"name\":\"SX10501: Power supply requirements - SPLat Controls\",\"isPartOf\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg\",\"datePublished\":\"2025-04-14T09:33:34+00:00\",\"dateModified\":\"2025-06-10T08:44:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg\",\"contentUrl\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg\",\"width\":265,\"height\":106},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product documentation\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Product documentation: Xwire peripherals\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"SX10501: Ultrasonic distance measurement + Non-Contact Temperature Measurement (Optional)\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"SX10501: Power supply requirements\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\",\"name\":\"SPLat Controls\",\"description\":\"OEM Embedded Machine Controllers\",\"publisher\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization\",\"name\":\"SPLat Controls\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg\",\"contentUrl\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg\",\"caption\":\"SPLat Controls\"},\"image\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SX10501: Power supply requirements - SPLat Controls","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"SX10501: Power supply requirements - SPLat Controls","og_description":"The board will run off 12VDC to 24VDC. Maximum current draw (TTL interface, RS485 termination link open) is 30mA. Using RS485 and 75 Ohms of...","og_url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/","og_site_name":"SPLat Controls","article_modified_time":"2025-06-10T08:44:49+00:00","og_image":[{"width":265,"height":106,"url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/","name":"SX10501: Power supply requirements - SPLat Controls","isPartOf":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website"},"primaryImageOfPage":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage"},"image":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage"},"thumbnailUrl":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg","datePublished":"2025-04-14T09:33:34+00:00","dateModified":"2025-06-10T08:44:49+00:00","breadcrumb":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#primaryimage","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg","contentUrl":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2025\/04\/SX10501-Power-.jpg","width":265,"height":106},{"@type":"BreadcrumbList","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/sx10501-power-supply-requirements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/"},{"@type":"ListItem","position":2,"name":"Product documentation","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/"},{"@type":"ListItem","position":3,"name":"Product documentation: Xwire peripherals","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/"},{"@type":"ListItem","position":4,"name":"SX10501: Ultrasonic distance measurement + Non-Contact Temperature Measurement (Optional)","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/product-documentation\/product-documentation-xwire-peripherals\/sx10501-ultrasonic-distance-measurement-non-contact-temperature-measurement-optional\/"},{"@type":"ListItem","position":5,"name":"SX10501: Power supply requirements"}]},{"@type":"WebSite","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/","name":"SPLat Controls","description":"OEM Embedded Machine Controllers","publisher":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/webprojects.cloud\/wordpress\/splatco\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization","name":"SPLat Controls","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg","contentUrl":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg","caption":"SPLat Controls"},"image":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase\/1882","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase"}],"about":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/types\/spl_knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/users\/1"}],"up":[{"embeddable":true,"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase\/1870"}],"wp:attachment":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/media?parent=1882"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}