{"id":2282,"date":"2025-04-15T09:32:48","date_gmt":"2025-04-15T09:32:48","guid":{"rendered":"https:\/\/webprojects.cloud\/wordpress\/splatco\/?post_type=spl_knowledgebase&#038;p=2282"},"modified":"2025-06-11T05:39:16","modified_gmt":"2025-06-11T05:39:16","slug":"goto-128-nvptr16","status":"publish","type":"spl_knowledgebase","link":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/","title":{"rendered":"GoTo &#8211; 128, NVPtr16"},"content":{"rendered":"\n<p>A ModBus Master script command. Don&#8217;t confuse with the regular\u00a0<code><a href=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/fasttrack-instructions\/goto-llll\/\">GoTo<\/a><\/code>\u00a0instruction.<\/p>\n\n\n\n<p>When processed this command will result in a jump to the script entry at NVEM0 address NVPtr16. This is the basic mechanism for making a script run in a continuous loop.<\/p>\n\n\n\n<p>Note that this command cannot be entered using a single\u00a0<code><a href=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/non-volatile-memory\/nv0byte-directive-d15\/\">NV0Byte<\/a><\/code>\u00a0directive, because an NVEM0 address cannot be specified in an NV0Byte list. Instead you need to use two lines. For example, if the target script line has the label Foo, the entry would be:<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">NV0Byte        128       ;GoTo<br>https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/non-volatile-memory\/nv0ptr-directive-d15\/         Foo<\/pre>\n","protected":false},"excerpt":{"rendered":"<p>A ModBus Master script command. Don&#8217;t confuse with the regular\u00a0GoTo\u00a0instruction. When processed this command will result in a jump to the script entry at NVEM0&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2271,"menu_order":9,"template":"","class_list":["post-2282","spl_knowledgebase","type-spl_knowledgebase","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>GoTo - 128, NVPtr16 - SPLat Controls<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GoTo - 128, NVPtr16 - SPLat Controls\" \/>\n<meta property=\"og:description\" content=\"A ModBus Master script command. Don&#8217;t confuse with the regular\u00a0GoTo\u00a0instruction. When processed this command will result in a jump to the script entry at NVEM0...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/\" \/>\n<meta property=\"og:site_name\" content=\"SPLat Controls\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-11T05:39:16+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/\",\"name\":\"GoTo - 128, NVPtr16 - SPLat Controls\",\"isPartOf\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website\"},\"datePublished\":\"2025-04-15T09:32:48+00:00\",\"dateModified\":\"2025-06-11T05:39:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Programming reference\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Instructions arranged by function\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Communications instructions\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"MODBUS Instructions\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/\"},{\"@type\":\"ListItem\",\"position\":6,\"name\":\"ModBus Master control script commands\",\"item\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/\"},{\"@type\":\"ListItem\",\"position\":7,\"name\":\"GoTo &#8211; 128, NVPtr16\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\",\"name\":\"SPLat Controls\",\"description\":\"OEM Embedded Machine Controllers\",\"publisher\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization\",\"name\":\"SPLat Controls\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg\",\"contentUrl\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg\",\"caption\":\"SPLat Controls\"},\"image\":{\"@id\":\"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GoTo - 128, NVPtr16 - SPLat Controls","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"GoTo - 128, NVPtr16 - SPLat Controls","og_description":"A ModBus Master script command. Don&#8217;t confuse with the regular\u00a0GoTo\u00a0instruction. When processed this command will result in a jump to the script entry at NVEM0...","og_url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/","og_site_name":"SPLat Controls","article_modified_time":"2025-06-11T05:39:16+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/","name":"GoTo - 128, NVPtr16 - SPLat Controls","isPartOf":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website"},"datePublished":"2025-04-15T09:32:48+00:00","dateModified":"2025-06-11T05:39:16+00:00","breadcrumb":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/goto-128-nvptr16\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/"},{"@type":"ListItem","position":2,"name":"Programming reference","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/"},{"@type":"ListItem","position":3,"name":"Instructions arranged by function","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/"},{"@type":"ListItem","position":4,"name":"Communications instructions","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/"},{"@type":"ListItem","position":5,"name":"MODBUS Instructions","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/"},{"@type":"ListItem","position":6,"name":"ModBus Master control script commands","item":"https:\/\/webprojects.cloud\/wordpress\/splatco\/knowledgebase\/programming-reference\/instructions-arranged-by-function\/communications-instructions\/modbus-instructions\/modbus-master-control-script-commands\/"},{"@type":"ListItem","position":7,"name":"GoTo &#8211; 128, NVPtr16"}]},{"@type":"WebSite","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#website","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/","name":"SPLat Controls","description":"OEM Embedded Machine Controllers","publisher":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/webprojects.cloud\/wordpress\/splatco\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#organization","name":"SPLat Controls","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/","url":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg","contentUrl":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-content\/uploads\/2024\/10\/logo.svg","caption":"SPLat Controls"},"image":{"@id":"https:\/\/webprojects.cloud\/wordpress\/splatco\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase\/2282","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase"}],"about":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/types\/spl_knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/users\/1"}],"up":[{"embeddable":true,"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/spl_knowledgebase\/2271"}],"wp:attachment":[{"href":"https:\/\/webprojects.cloud\/wordpress\/splatco\/wp-json\/wp\/v2\/media?parent=2282"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}